Súper estación de carga de refrigeración líquida

LHKCEDC2-480KW/2L/GB-10 is an innovative liquid-cooled booster architecture that uses the most advanced liquid cooling technology and DC bus architecture. The charging host can realize energy conversion and power distribution, with a maximum output power of 720 kilovatios.

Introduction of Product

LHKCEDC2-480KW/2L/GB-10 is an innovative liquid-cooled boost architecture developed by an industry-leading company for electric vehicle charging. Unlike traditional air-cooled integrated systems, it uses the most advanced liquid cooling technology and DC bus architecture. The system consists of a charging host and a charging terminal. The charging host can realize energy conversion and power distribution, with a maximum output power of up to 720 kilovatios. It has built-in 120 kW AC/DC and 60 kW DC/DC liquid cooling modules and power sharing units, which can achieve 12-channel line output. The terminal is optional and configurable, supporting both liquid cooling and natural cooling.

Características del producto:

  • Ultra-Fast Integration: Incorporates a supercharging system that maximally supports 12-channel line output.
  • Supports Mixed Liquid-Cooled and Air-Cooled Terminals: Offers compatibility for a combination of liquid-cooled and natural-cooled terminals.
  • Charging Host with Liquid-Cooled Terminals: The charging host, when paired with liquid-cooled terminals, supports 480kW constant power output.
  • Liquid Cooling System: Ensures safety and reliability through water-electric isolation design. Supports long-term use with board-and-liquid transport, featuring an integrated die-cast liquid-cooled charging module with a lifespan of 10 years. Environmentally friendly and efficient, with the charging host achieving an end-to-end efficiency of 95%+.
  • Direct Current Busbar: Utilizes power pooling and intelligent algorithms to effectively enhance grid utilization rates. Supports smooth DC stacking storage, thereby increasing the end-to-end efficiency of the entire station.

This charging pile is suitable for fast charging of new energy vehicles, providing users with convenient and efficient charging services, and is an advanced choice for the next generation of new energy vehicle charging equipment.

Charging host specifications

Basic information Product model LHKCDC3-720KW/12L/GB-10
Dimensiones (width*depth*height) 800 mm x1700 mm x 2150 milímetros
Installation method Floor-mounted (supports transport with board and liquid)
System efficiency Maximum efficiency 95.5%
Rated power 600kw
Cooling method Liquid cooling
Protection level IP55
Number of guns supported 4-12
Communication interface 4G, FE (northbound)
Input characteristics Input voltage 380Vac+15%, three-phase five-wire system
Input frequency 45Hz ~ 66Hz
Input current 1150 A
Power factor 0.99 (load>50%)
Harmonics ≤5% (load>50%)
Input power distribution AC 800Ax3P circuit breaker; single transformer 2-way incoming line (360KW per line)
Output characteristics Output voltage 200-1000Vdc
Current regulation accuracy ≤+1%
Voltage regulation accuracy ≤±0.5%
Environmental indicators Working temperature -35*C~+50*C
Storage temperature -35*C~+70°C
Altitude ≤2000m
Relative humidity 5%RH ~95%RH
Noise level ≤55 dB@25°C (quiet mode), ≤65 dB@25”C (standard mode)
Safety function Input overvoltage protection, undervoltage protection, output overvoltage protection, constant power overload protection, short circuit protection, grounding protection, overtemperature protection, lightning protection, emergency stop protection, leakage protection, insulation detection, door opening protection, battery reverse connection protection, relay adhesion protection, water immersion protection, smoke alarm.
Product specification GB/T18487.1-2015,NB/T33001-2018,NB/T33008.1 -2018
Host terminal communication interface FE, recommended ring network, screen twisted pair FTP Cat5E
Host terminal communication protocol GOOSE+ MODBUS -TCP
Auxiliary power supply standard Host 220Vac auxiliary power supply output

Accessories Specifications

Basic information Product model Supercharger terminal DC fast charging terminal
Charging power Maximum 600KW Rated 360kw, single gun 180KW
Dimensiones (width*depth*height) 340*295*1700 390*295*1700
Número de armas de carga 1 2
Gun line length 3.5metro 5metro
Installation method Floor mounted Floor installation
Protection level IP55 IP55
Heat dissipation method Liquid cooling Natural cooling
Environmental indicators Working temperature -35~+50°C -35~+50°C
Noise level ≤55dB-25°C ≤50dB@25°C
Storage temperature -35°C~+70°C -35°C~+70°C
Relative humidity 5%RH ~95%RH 5%RH ~95%RH
Altitude ≤2000m ≤2000m
Output characteristics Output voltage 200~1000Vdc 200~1000Vdc
Charging current Maximum 600A 250A
Product specification   GB/T27930-2015.JG1149-2022 GB/T18487.1-2015, NB/T33001-2018.NB/T33008.1-2018, GB/T27930-2015.JG1149-2022
Safety function Output overvoltage protection, short circuit protection, protective grounding continuity detection, over-temperature protection, emergency stop protection, electrical protection, insulation detection, door opening protection, power failure protection, battery reverse connection protection, contactor adhesion protection, low liquid level alarm

Soluciones de productos

DEMANDA DEL USUARIO

  • Dispuesto a invertir en la construcción de estaciones de carga.
  • Espero mejorar el equipo de la estación de carga existente.
  • Esperamos proporcionar instalaciones de servicio de soporte de carga para edificios residenciales.
  • Tiene canales de clientes y espera convertirse en un agente para vender pilas de carga.
  • Tener una estación con pilas de carga., pero no hay plataforma de gestión de carga
  • Esperamos mejorar el funcionamiento de las estaciones de carga existentes y aumentar los ingresos.
  • Tener recursos del sitio y esperar construir una estación.
  • Tener recursos energéticos y esperar construir una estación.

SOLUCIÓN

  • Proporcionar varios tipos de pilas de carga para satisfacer las necesidades de diferentes escenarios de carga.
  • Proporcionar una política completa de agencia distribuidora.
  • Proporcionar soluciones flexibles de servicios financieros de ventas de pilas de carga

  • Servicios de acceso a la plataforma de carga, usuarios de plataforma compartida
  • Servicios de liquidación flexibles

  • Soluciones personalizadas (evaluación del sitio, informe del estudio de viabilidad del cálculo del rendimiento de la inversión, etc.)
  • Servicios profesionales del equipo de operación y mantenimiento.

Smart and orderly charging station

A-single-phase-AC-charging-pile

Estación de carga rápida dedicada

Pila de carga de potencia constante de CC

Introducción a la investigación y el desarrollo.

Microrred

Una parte vital de las redes inteligentes, Las microrredes funcionan de forma fiable tanto en modo fuera de la red como conectado a la red., permitiendo la interacción inteligente entre la generación distribuida, almacenamiento de energía, e instalaciones de carga. Con sistemas avanzados de gestión de energía., aseguran la estabilidad del sistema, optimizar el uso de energía, y minimizar las pérdidas al tiempo que respalda la utilización de circuito cerrado de energía renovable, contribuyendo a la neutralidad de carbono.

EMS

Sirviendo como control central de la microrred, EMS gestiona los datos, monitores, controles, y optimiza las operaciones del sistema de almacenamiento de energía de manera eficiente. Ajusta los parámetros de potencia y voltaje para satisfacer las demandas de carga., coordina con la red principal, y reduce el consumo de energía y las pérdidas del sistema. EMS también facilita la operación en isla y las estrategias de recierre, Garantizar la confiabilidad del sistema durante fallas..

EMEWS

Este sistema monitorea las operaciones de la microrred en tiempo real, incluyendo fotovoltaica, almacenamiento de energía, e instalaciones de carga, Mejorar la eficiencia operativa a través del análisis de datos y advertencias inteligentes.. Equipado con interfaces de comunicación y gestión de batería., identifica rápidamente los problemas, admite la programación integrada de estaciones de energía, y proporciona datos para advertencias de seguridad pública..

FABRICACIÓN DE PILAS DE CARGA

Una pila de carga de CA monofásica

Materias primas

Carcasa de pila de carga, tarjeta de circuitos, batería, motor, sensores, etc..

Producción de ensamblaje

Ensamble los diversos componentes de acuerdo con los dibujos de diseño para garantizar que la pila de carga cumpla con el rendimiento eléctrico y mecánico estándar..

Pruebas y depuración

Después del montaje, El personal de producción debe realizar pruebas y depuraciones en la pila de carga para garantizar que el rendimiento cumpla con los estándares.. Se trata de controles de apariencia., rendimiento de aislamiento, rendimiento eléctrico, y pruebas en carretera para garantizar un rendimiento estable en diversos entornos.

Una pila de carga de CA monofásica

EXPOSICIÓN HAL INTRODUCCIÓN

pila de carga

ESCENARIOS DE APLICACIÓN

Contáctenos

Analice sus necesidades de mercado y vehículos

Cuéntanos tu mercado, tipo de vehículo y datos de contacto. Our team will respond with a suitable next step.

HESU apoya a los distribuidores extranjeros, importadores y compradores de flotas con comunicación práctica sobre el siguiente paso basada en el mercado y los requisitos del vehículo.